It is not designed for use with motor-type equipment. The Back-UPS ES may require service. Contact APC Technical Support for further troubleshooting. The Power On indicator is lit and the BackUPS ES is beeping four times every 30 seconds. The Back-UPS ES is using battery. The Back-UPS ES is operating normally and using battery power. The Back-UPS ES may require service. Contact APC Technical Support for further troubleshooting. The Power On indicator is lit and the Back-UPS ES beeps four times every 30 seconds. The Back-UPS ES is On Battery. The Back-UPS ES is operating normally, and using battery power. Once On Battery, you may want to save your current work, power down.
All other trademarks are property of their respective owners.
The Back-UPS ES is shipped with one battery wire disconnected in compliance with Department of Transportation (DOT) regulations. The Back-UPS ES will not operate until the wire is connected to the touch safe battery terminal.
NOTE: Small sparks may occur during battery connection. This is normal.
Apc Backup Ups 350 Manual
1
2
4
TURN the Back-UPS ES over and remove the battery compartment cover screw using a flat blade or phillips-head screwdriver.
Slide the battery compartment cover completely off of the Back-UPS ES.
Replace the battery, battery compartment cover and cover retaining screw.
Surge Protection
These outlets provide full-time protection from surges even if the Back-UPS ES is switched OFF. Plug your printer, fax machine, scanner, or other peripherals that do not need battery power into these outlets.
Battery Back-up
Try the Classic Typewriter Pagewebsite for Smith-Corona manuals.Youcan also checkManualsfor Specific TypewritersJohnesimmons.comhas a manual for.SmithCorona Portables (form Machine’s of Loving Grace website)RepairManualsIf you’re planning to repair or restore your antique Remingtontypewriter, you’ll need a repair manual. Ifyou’ve recently purchased an antique Smith-Corona typewriter, one of the firstthings that you’ll need is a User manual. Smith corona coronet electric 10 user manual pdf 2 8. Here are a couple of sources; I’vefound with repair manuals that you can download.Typewriter Repair Manuals from TheClassic Typewriter Page, (bottom of the page).
plus Surge Protection
These outlets are powered whenever the Back-UPS ES is switched ON. During a power outage or other utility problems (brownouts, over-voltages), these outlets will be powered for a limited time by the Back-UPS ES. Plug your computer, monitor, and one other data-sensitive device (external disk or tape drive) into these outlets.
Connect FAX/Modem/Phone
Back-UPS ES protects a single line (2-wire) fax, modem or phone from surges when it is connected through the Back- UPS ES as shown.
Place the Back-UPS ES to avoid:
Apc Back Ups Es 350 User Manual 2016
- Direct sunlight - Excessive heat - Excessive humidity or contact with fluids
Plug the Back-UPS ES power cord directly into a wall outlet; not a surge protector or power strip.
Connect Computer Cable
The supplied cable and software provide automatic file saving and shutdown of the operating system in the case of a sustained power outage.
Connect the cable to the Data Port of the Back- UPS ES. Connect the other end of the cable to the USB port on your computer. The software will automatically find the USB Port of your computer.
Press the ON/OFF switch to power the unit ON.
A single short beep and the green “Power On” indicator confirms that Back-UPS ES is on and ready to provide protection.
The Back-UPS ES should charge for at least 16 hours to ensure sufficient runtime. The unit is being charged whenever it is connected to utility power, whether the unit is turned ON or OFF.
If the red Building Wiring Fault indicator (located on the end near the power cord) is lit, your building wiring presents a shock hazard that should be corrected by a qualified electrician.
Install the PowerChute Personal
®
Edition
software
Place the PowerChute Personal Edition CD- ROM into your computer and follow the installation instructions on the screen.
3
LIFT the battery out of the compartment and connect the black wire to the battery terminal.
www.apc.com
®
P o w e r O n
Battery Backup
plus Surge Protection
Wall Outlet
Modem/Phone/Fax
Computer
USB Port
Surge Protection
Back-UPS ES 500
Back-UPS ES 350
APC, Back-UPS and PowerChute are registered trademarks of American Power Conversion Corp.
The Back-UPS ES indicates operating status using a combination of visual and audible indicators.
Status
Visual Indications
Audible Indication
Alarm Terminates
When
On Line - UPS is supplying conditioned utility power to the load
Power On LED - ON
None
n/a
On Battery - UPS is supplying battery power to the load connected to the Battery outlets
Power On LED - ON (off during beep)
Beeping 4 times every 30 seconds
2 PAC Vision Overview System Overview PAC Vision provides a 32-bit, multiple user, and multiple division access control solution that uses the Windows XP operating system, retains existing user. Pac vision 2.0 user manual update.
UPS transfers back to On Line operation, or when UPS is turned off.
Low Battery Warning - UPS is supplying battery power to the load connected to the Battery outlets and the battery is near exhuastion
Power On LED - Flashing
Rapid beeping (one second intervals)
UPS transfers back to On Line operation, or when UPS is turned off.
Replace Battery - Battery needs to be checked and/or replaced, or battery is not connected
Apc Back Ups Es 350 User Manual Free
Power On LED - Flashing
Constant tone
UPS turned off with the power switch.
Overload Shutdown - During On Battery operation a battery power supplied outlet overload was detected.
Power On LED - OFF
Constant tone
UPS turned off with the power switch.
Sleep Mode - During On Battery operation the battery power has been completely exhausted and the UPS is waiting for utility power to return to normal.
Power On LED - OFF
Beeping once every 4 seconds
UPS transfers back to On Line operation, or when UPS is turned off.
Building Wiring Fault - Your building wiring presents a shock hazard that should be corrected by a licensed electrician.
Building Wiring Fault LED (red) - ON
None
UPS is unplugged, or plugged into a properly wired outlet.
Status Indications
Power On
Circuit
Breaker
AC Line
Cord
Building Wiring
The last thing anyone at a LAN party want to see is your butt crack asyou reach around in the dark fiddling with audio cables prior to the big game.right!? The headers have suitably long jumper cables to reach the motherboardfront panel headers. Cooler master haf 932 manual pdf.
Fault Indicator
UPS Power
On Indicator
Power
Switch
®
See the Troubleshooting section for additional assistance.